The right solar inverter for a home depends mostly on three things: how much the home uses, what connection it has, and whether the power goes out often. Room count is only a rough proxy for the first of those. This guide starts from home size, from a one-bedroom flat to a large villa, and shows the inverter capacity range, the system type and example models with their own datasheet figures at each step.
If you already have a quote and want to test it, use the 8-point checklist for choosing a solar inverter for home. If you want ten brands compared model by model, use the best solar inverter in India comparison. This page is about what size and type to look for, and which exact models to put on the shortlist at each size.
Disclosure: Qbits publishes this guide and sells solar inverters. Qbits models appear next to models from other brands, using each maker’s own published documents. Prices and payback periods are left out on purpose: Qbits pricing is quote-based through dealers, and public prices rarely cover the same scope.
Why home sizing is different from commercial sizing
A factory’s load is steady and predictable. A home’s load is spiky: a compressor starts, a pump runs, an air conditioner cycles with the weather. Three separate numbers matter and homeowners often merge them:
| Number | What it is | What sets it |
|---|---|---|
| Rooftop solar capacity (kWp) | Panel capacity on the roof | Monthly consumption, usable roof area, shade |
| Inverter AC rating (kW) | What the inverter can feed the home and grid | Array size, phase, sanctioned load, DISCOM rules, model limits |
| Backup power and battery (kW, kWh) | What runs during a cut, and for how long | Critical loads and hours, battery limits |
An inverter for a 5 kWp array is not always a 5 kW inverter. Many designs run the array a little above the inverter’s AC rating, within the maker’s stated limits. And outage backup is a separate calculation from the solar array. See the solar inverter sizing guide and DC oversizing explained.
Inverter by home size: quick-reference table
Home types are a rough guide only. Two three-bedroom homes can use very different amounts of power. The capacity ranges below follow the monthly-consumption guide in a PIB release on the PM Surya Ghar scheme dated 5 December 2024: 0 to 150 units a month suits 1 to 2 kW, 150 to 300 units suits 2 to 3 kW, and above 300 units suits above 3 kW, read October 2026. Above that threshold, the right size is a design decision.
| Home type (rough guide) | Typical rooftop capacity range | Inverter type to check | Phase to check | Example families to read |
|---|---|---|---|---|
| Small flat or 1 BHK, low consumption | 1 to 2 kW | On-grid; hybrid if cuts are frequent | Single | QB 1.5 to 4.0 KTLS; see per-size picks below |
| 2 BHK, moderate consumption | 2 to 3 kW | On-grid; hybrid if cuts are frequent | Single | QB 1.5 to 4.0 KTLS (up to 4 kW rating); QBH 3 to 6 KS48P for backup |
| 3 BHK, higher consumption | 3 to 6 kW | On-grid; hybrid for power-cut zones | Single, or three-phase if your connection is | QB 4.2/4.6/5/5.4/6KTLS or QB 4/5/6 KTLD; QBH 3 to 6 KS48P |
| 4 BHK, bungalow or large home | 5 to 10 kW | On-grid or hybrid | Often three-phase; check | QB 6 to 17 KTLC three-phase; QBH 7 to 8 KS48P |
| Villa or home with heavy loads (EV, multiple air conditioners, pumps) | 8 kW and above | Hybrid if backup matters | Usually three-phase | QB 6 to 17 KTLC; QBH 5 to 12 KS48P3 hybrid |
The home fit matrix
Work down three questions. Each narrows the answer. The output is a category and a size band, not a brand.
- Home size and consumption: gives the kW band from the table above.
- Power-cut frequency: decides the type. Occasional cuts of an hour or so rarely justify a battery; a home that loses power for hours every day, or at the times when air conditioners or pumps run, is a hybrid candidate.
- Connection: single-phase or three-phase, and what your DISCOM allows.
| Home size | Power cuts | Output category |
|---|---|---|
| Small (1 to 2 kW band) | Rare | On-grid single-phase |
| Small (1 to 2 kW band) | Frequent | Hybrid single-phase with a small battery, loads limited to the essentials |
| Mid (2 to 6 kW band) | Rare | On-grid single-phase, dual-MPPT if the roof has two planes |
| Mid (2 to 6 kW band) | Frequent | Hybrid single-phase with a battery sized to the critical loads |
| Large (6 kW and above) | Rare | On-grid, three-phase if the connection is three-phase, dual-MPPT or more |
| Large (6 kW and above) | Frequent | Hybrid, three-phase where applicable, with a plan for which large motors stay off battery |
The matrix is a starting point. A site survey can move the answer by a size. Use the string sizing calculator to check panel strings once you know the module.
On-grid versus hybrid for Indian homes
The biggest decision is on-grid or hybrid, and it is hard to reverse later.
| Strengths | Limits | |
|---|---|---|
| On-grid | Simplest design; suited to grid-connected generation and net metering; fewer parts to service | Stops feeding power when the grid fails, so no solar-backed loads during a cut; no battery port |
| Hybrid | Can run selected loads from a battery during a cut; the battery can charge from solar; can support export-limit settings on some models | More parts and a battery to buy and service; backup covers defined loads, not necessarily the whole home; the battery must be on the maker’s supported list |
If a hybrid is out of reach today but may be needed later, ask whether the inverter can support a battery later, and which battery models, in writing. A grid-tied string inverter normally has no battery port.
Example models by home size, with datasheet figures
These are example families to read, not recommendations. Every figure comes from the maker’s own datasheet or product record, read October 2026. Do not copy a figure from one model to another.
1 BHK and small flats (about 1 to 2 kW)
| Model | Phase | MPPT | MPPT window | Max input current | Max efficiency | IP | Source |
|---|---|---|---|---|---|---|---|
| Qbits QB 1.5/2.0 KTLS (in the QB 1.5 to 4.0 KTLS family) | Single | 1 | 40–550 V | 20 A | 98% (family) | IP66 | Qbits datasheet, model page |
| Havells Enviro GTi 2.2 KT G3 | Single | 1 | 50–500 V | 14 A | 97.30% | IP65 | Havells brochure |
| UTL single-phase 2 kW | Single | 1 | 70–500 V | 20 A | 97.3% | IP65 | UTL datasheet |
A single MPPT is usually enough for one roof plane. Check that the planned string voltage and current fit the window and current limit. If the home has frequent cuts, a small hybrid is the category to evaluate instead.
2 BHK (about 2 to 3 kW)
| Model | Phase | MPPT | MPPT window | Max input current | Max efficiency | IP | Source |
|---|---|---|---|---|---|---|---|
| Qbits QB 3.0/3.3/3.6 KTLS (in the QB 1.5 to 4.0 KTLS family) | Single | 1 | 40–550 V | 20 A | 98% (family) | IP66 | Qbits datasheet |
| Havells Enviro GTi 3.3 KT G3 | Single | 1 | 50–550 V | 15 A | 97.70% | IP65 | Havells brochure |
| Waaree single-phase 3000 | Single | 1 | 50–480 V | 20 A | 97.4% | IP65 | Waaree brochure, 0.7 to 3.3 kW table |
For a 3 kW comparison across more brands see the 3 kW inverter guide. The 2 kW guide and 1 kW guide cover the smaller sizes.
3 BHK (about 3 to 6 kW, on-grid)
| Model | Phase | MPPT | MPPT window | Max input current | Max efficiency | IP | Source |
|---|---|---|---|---|---|---|---|
| Qbits QB 4/5/6 KTLD (5KTLD is 5000 W) | Single | 2 | 80–550 V | 20/20 A | 98.1% | IP66 | Qbits datasheet, model page |
| Qbits QB 4.2 to 6 KTLS family | Single | 1 | 40–600 V | 20 A | 98.0 to 98.1% by model | IP66 | Qbits datasheet, model page |
| Havells Enviro GTi 5000 D-NG | Single | 2 | 80–550 V | 15/15 A | 98.4% | IP65 | Havells brochure |
| Sungrow SG5.0RS-L | Single | 2 | 40–560 V | 16/16 A | 97.9% | IP65 | Sungrow India page |
More 5 kW models, with the same fields, are in the 10-brand comparison and the 5 kW guide. The 6 kW guide covers the top of this band.
3 BHK or larger homes in power-cut areas (about 3 to 6 kW, hybrid)
| Model | Phase | MPPT | MPPT window | Max DC | Max input current | IP | Source |
|---|---|---|---|---|---|---|---|
| Qbits QBH 3/3.6/4/4.6/5/6 KS48P hybrid | Single | 1 or 2 by model | 150–450 V | 500 V | 3KS48P: 18 A; others 18/18 A | IP66 | Qbits hybrid catalogue, model page |
| Fronius Primo GEN24 5.0 | Single | 2 | 230–530 V | DC input range 65–600 V | 22 A / 12 A | IP66 | Fronius India page |
The QBH family has a 48 V battery input, 75 to 120 A battery current by model, and accepts lead-acid or lithium subject to compatibility. Ask which exact battery models are supported, who warrants the battery, and which circuits sit on the backup path. Fronius documents a battery-ready platform with an integrated backup socket; confirm the India variant. See the hybrid inverter range, the hybrid inverter guide and the battery sizing guide.
4 BHK, bungalows and villas (about 6 to 10 kW and above)
| Model | Phase | MPPT | MPPT window | Max DC | Max input current | IP | Source |
|---|---|---|---|---|---|---|---|
| Qbits QB 6 to 17 KTLC (10KTLC is 10 kW) | Three | 2 | 180–1000 V | 1100 V | 20/20 A (6 to 12 kW models) | IP66 | Qbits datasheet, model page |
| Havells Enviro GTi 11000 TX-NG (10 kW) | Three | 2 | 140–1000 V | 1100 V | 15/15 A | IP65 | Havells brochure |
| UTL F series 10 kW (GT-10P0-GX-T2) | Three | 2 | 200–1000 V | 1100 V | 20 A per MPPT | IP65 | UTL datasheet |
If you need backup at this size, the QBH 7/7K6/8 KS48P single-phase hybrid and the QBH 5 to 12 KS48P3 three-phase hybrid are the Qbits families to read; their datasheets list different MPPT windows (150–450 V and 200–800 V) and battery currents by model. See the 3 kW vs 5 kW vs 10 kW guide and the 10 kW guide.
Sizing worked examples: from loads to inverter and battery
These examples show the method. The appliance wattages are illustrative nameplate-style values, not measurements of your home. Measure or check labels for yours, and let a designer confirm.
Step 1. List loads that run together at a hot-afternoon peak. Include air conditioners, refrigerator, fans, lights, TV and always-on devices. Step 2. Add running watts. Use labels or a plug-in meter. Air conditioner draw varies widely by model, age and whether it is inverter-driven. Step 3. Allow for starting surge. Compressors and pumps draw several times their running power for a moment. A common planning margin is 1.25 times the simultaneous load, plus headroom for growth, but the inverter’s own surge rating is what counts for backup. Step 4. Separate the three numbers. Array size from consumption, inverter AC rating from array and phase, backup output and battery from critical loads.
1 BHK example (illustrative)
One 1-tonne air conditioner (about 1,000 W running), a refrigerator (150 W), two fans (150 W), a TV (100 W) and lights (100 W) add up to about 1,500 W. With a 1.25 times surge allowance that is roughly 1,900 W. A 2 or 3 kW grid-tied inverter covers it comfortably. An inverter below 2 kW would leave little margin if the air conditioner and refrigerator start together, and a 1.5 kW model is only right if the array and loads are smaller still.
2 BHK example (illustrative)
Two 1.5-tonne air conditioners (about 3,000 W together), a refrigerator (200 W), a washing machine (500 W, intermittent), four fans (300 W) and lights (150 W) add up to about 4,150 W. If both air conditioners rarely run at the same time, the real simultaneous load is lower. The grid-tied inverter is sized from the array and phase, not from this number, so a 3 to 5 kW inverter is typical. For backup you would not try to run both air conditioners from a battery.
3 BHK example with backup (illustrative)
Phase and connection by home size
Small homes are usually on a single-phase supply. Larger homes may have three-phase connections, and some DISCOMs limit single-phase solar capacity. Rules differ by state and distribution company, and change by order, so do not rely on a rule of thumb such as “above 5 kW needs three-phase”. Check your bill and meter, then ask the DISCOM or the installer in writing. See single-phase versus three-phase and the DISCOM approval guide.
Let the roof pick the MPPT count
One roof plane with uniform shade works with one MPPT input. Two planes, such as east and west, often suit two independent inputs. The count does not fix shade inside a string. For each string, the designer must check cold-morning open-circuit voltage against the maximum DC voltage, hot-day operating voltage against the MPPT window, and current against the input limit. See the dual versus single MPPT guide and the east-west roof design guide.
Subsidy and sizing under PM Surya Ghar
For residential rooftop systems, MNRE’s scheme annexure of August 2024 sets central financial assistance at Rs 30,000 per kWp for the first 2 kWp and Rs 18,000 per kWp for the additional 1 kWp, with no additional assistance beyond 3 kWp (special category states have higher rates). Read the MNRE annexure and check the official pmsuryaghar.gov.in portal, your state agency and DISCOM for the current rules, vendor registration steps and timelines, since they change. Subsidy approval is a DISCOM and MNRE decision and is never guaranteed by an installer. See the subsidy amount guide for detail.
Monitoring, warranty and service for a home system
Monitoring. Confirm the monitoring route for the exact model, who owns the account, and that live data appears at the mounting location. See the monitoring guide.
Warranty. Ask for the written warranty of the exact model. The public Qbits datasheets describe an expandable warranty but do not define the base term, remedy, registration deadline or exclusions, so request the current terms. Do the same with every other brand. See the warranty guide.
Service. Ask for the named service party for your PIN code. The authorised service partner directory shows published Qbits partners by state and district, and you should ask whether the partner supports your exact model.
Common mistakes homeowners make
- Sizing by room count. Use bills, roof and DISCOM limits.
- Choosing on-grid in a power-cut area. The system stops when the grid fails.
- Planning for today’s load only. If an electric vehicle charger or a second air conditioner is likely, size the connection, phase and inverter headroom for it, within DISCOM limits.
- Assuming a family name fixes the spec. The QB 1.5 to 4.0 KTLS and QB 4.2/4.6/5/5.4/6KTLS families are both single-MPPT, but their windows differ.
- Skipping monitoring checks. An unconfigured app is not monitoring.
- Not checking the installer’s registration if you plan to claim a subsidy.
- Paying before the exact model, documents and service route are written down. The quotation checklist helps.
Next steps
Pick your home size band, decide on-grid or hybrid from your outage pattern, then open the datasheets for two or three exact models in that band and compare them on the same fields. If a Qbits model is on your shortlist, start from the residential solution page, and keep your bills, phase, roof layout, outage needs and proposed model documents ready.
Sources checked October 2026: PIB release of 5 December 2024 on PM Surya Ghar; MNRE scheme annexure (August 2024); Qbits product records and datasheets; Havells GTi brochure; UTL on-grid F series datasheet; Waaree inverter brochure; Sungrow and Fronius India product pages.
Qbits inverters for this guide
Specs below come from each model's datasheet. Confirm the exact model and current written terms with Qbits before you buy.
QB 4.2/4.6/5/5.4/6KTLS
- Power
- 4.2–6 kW
- Phase
- Single-phase
- MPPT
- Single-MPPT
QB 4/5/6 KTLD
- Power
- 4–6 kW
- Phase
- Single-phase
- MPPT
- Dual-MPPT
QBH 3KS/3K6S/4KS/4K6S/5KS/6KS48P
- Power
- 3–6 kW
- Phase
- Single-phase
- MPPT
- 1 or 2 MPPTs by model
Frequently Asked Questions
Which solar inverter should I buy for my home in India?
What size solar inverter does my home need?
Is an on-grid or hybrid solar inverter better for a home?
Should a home use a single-phase or three-phase solar inverter?
How many MPPTs should a home solar inverter have?
What documents should I get before buying a solar inverter?
How many kW inverter does a 1 BHK, 2 BHK or 3 BHK home need?
What is the price of a home solar inverter?
Can a hybrid inverter run my air conditioner during a power cut?