Skip to content
Performance Updated October 14, 2026

Temperature Coefficient

Quick Definition

Temperature coefficient is the percentage change in solar module electrical parameters (Pmax, Voc, Vmp, Isc) per degree Celsius rise above STC (25°C). Pmax coefficient typically -0.26 to -0.37 percent/°C. Critical for Indian climates where module temperatures regularly reach 60-80°C.

Quick Facts

Term
Temperature Coefficient
Category
Performance
Industry
Solar Module Performance
Primary Use
Yield prediction in hot climates
Common Users
Designers, EPCs, yield modellers
Standards
IEC 61215, IEC 61853
Related Technologies
Cell technology, module construction

What is temperature coefficient

Temperature coefficient is the percentage change in a solar module’s electrical parameters per degree Celsius change in operating temperature above Standard Test Conditions (STC = 25°C cell temperature). Three coefficients are reported in module datasheets:

  • Voc temperature coefficient (β_Voc or simply β): change in open-circuit voltage. Typically -0.27 to -0.30%/°C for PERC.
  • Isc temperature coefficient (α_Isc): change in short-circuit current. Slightly positive, typically +0.04 to +0.06%/°C.
  • Pmax temperature coefficient (γ_Pmax): change in maximum power. Typically -0.34 to -0.37%/°C for PERC.

The Pmax coefficient is the most important for yield calculation. A PERC module at 60°C cell temperature (35°C above STC) loses approximately 35 × 0.36% = 12.6% power compared to STC. In Indian summer conditions, this loss is the dominant performance derate, explained in detail in why solar inverters produce less in Indian summer.

For Indian solar, temperature coefficient is critical because rooftop and ground-mount panels regularly reach 60-80°C in summer. Cell technologies with better coefficients (HJT, TOPCon) provide measurable yield advantages in hot climates.

Why temperature coefficient matters

Hot climate yield. Indian summer cell temperatures reach 75-80°C; lower coefficient means less yield loss.

Cell technology selection. HJT’s superior coefficient and higher module efficiency justify a premium in hot regions.

String sizing. Voc coefficient determines cold-morning Voc derate.

Yield modelling. Required input for accurate solar yield simulations, including tools such as SurgePV’s solar simulation software.

Lifecycle yield. Cumulative impact over 25 years is significant.

Temperature coefficient by cell technology

Voc and Pmax temperature coefficients by cell technology
CellVoc coefficientPmax coefficient
PERC-0.27 to -0.30%/°C-0.34 to -0.37%/°C
Mono-PERC bifacial-0.27 to -0.30%/°C-0.34 to -0.36%/°C
TOPCon-0.25 to -0.28%/°C-0.30 to -0.33%/°C
HJT-0.21 to -0.25%/°C-0.24 to -0.28%/°C
IBC-0.27 to -0.30%/°C-0.27 to -0.30%/°C
Thin film CdTe-0.22 to -0.28%/°C-0.21 to -0.25%/°C

Technical deep dive

Power loss vs temperature (PERC γ = -0.36%/°C)

Power loss versus STC by cell temperature for a PERC module (γ = -0.36%/°C)
Cell temperatureLoss vs STC
25°C (STC)0%
35°C3.6%
45°C7.2%
55°C10.8%
65°C14.4%
75°C18.0%
%0510152025°C35°C45°C55°C65°C75°C0%3.6%7.2%10.8%14.4%18%%0510152025°C35°C45°C55°C65°C75°C0%3.6%7.2%10.8%14.4%18%
PERC module power loss versus STC by cell temperature
ItemValue (%)
25°C0%
35°C3.6%
45°C7.2%
55°C10.8%
65°C14.4%
75°C18%
PERC module power loss versus STC by cell temperatureSource: Calculated in this entry as (cell temperature minus 25°C) multiplied by the PERC Pmax coefficient of 0.36%/°C, per the table aboveLower is better. A module at -0.26%/°C (HJT) sits roughly 28% below these values at every temperature.

HJT vs PERC at high temperature

At 60°C cell temperature:

  • PERC (γ = -0.36%/°C): 35 × 0.36 = 12.6% loss
  • HJT (γ = -0.26%/°C): 35 × 0.26 = 9.1% loss
  • HJT advantage: 3.5 percentage points

Across Indian summer (≈800 hours at cell temp > 60°C):

  • HJT delivers 2-4% more annual yield

NOCT-based estimation

NOCT (Nominal Operating Cell Temperature) is the cell temperature at 800 W/m², 20°C ambient, 1 m/s wind.

Cell temperature approximation: T_cell = T_ambient + (NOCT − 20) × (Irradiance / 800)

For NOCT = 45°C and Indian summer ambient 40°C with 1,000 W/m²: T_cell = 40 + (25) × (1000/800) = 40 + 31 = 71°C

Test method (IEC 61853)

Module measured at multiple temperatures (25°C, 50°C, 75°C) and irradiance levels (1000, 800, 500, 200 W/m²). Coefficients extracted by linear fit.

Real-world applications

PVsyst yield modelling input.

String sizing cold/hot calculations.

Module selection for hot climates, part of a broader strategy to maximise solar output in Indian conditions.

Bankable yield assessment.

Best practices

Use module datasheet values for yield modelling.

Verify IEC 61853 measurement test.

Account for temperature derating in PR.

For hot Indian sites, prefer TOPCon or HJT.

Document temperature coefficient assumption in yield models.

Indian market context

Indian summer cell temperatures: 65-80°C common.

Temperature derate dominates in mid-day yield modelling.

HJT premium increasingly justified in dry hot regions (Rajasthan, Gujarat), where detailed rooftop engineering design accounts for elevated cell temperatures.

ALMM-listed modules report standard coefficients.

Standards and certifications

Standards that govern temperature coefficient measurement and use
StandardScope
IEC 61853Module performance measurement
IEC 61215Module qualification
IS 14286Indian module standard
Manufacturer datasheetsSpecific values

Key takeaways

Temperature coefficient measures power loss per degree of cell temperature rise above STC. Critical for Indian climates where cell temperatures regularly reach 60-80°C. PERC: -0.34 to -0.37%/°C. TOPCon: -0.30 to -0.33%/°C. HJT: -0.24 to -0.28%/°C. HJT’s superior coefficient provides 2-4 percent more annual yield in hot Indian conditions, often justifying its price premium.

Further reading

For how Temperature Coefficient plays out in real projects, these guides go deeper:

Sources

  • IEC 61853, Module performance measurement.
  • IEC 61215, Module qualification.
  • IS 14286, Indian module standard.
  • ITRPV Roadmap, latest edition.
  • Manufacturer datasheets from major module brands.
  • NREL Module Temperature Studies.
  • Sandia National Laboratories module temperature reports.
  • IEA PVPS Task 13 Reports.
  • Duffie J. A., Beckman W. A., Solar Engineering of Thermal Processes, Wiley.
FAQ

Frequently Asked Questions

What is temperature coefficient in simple words?
How much your solar panel's power drops for every degree it gets hotter than 25°C. Lower (more negative) coefficient means more heat loss.
What are typical Pmax coefficients?
PERC: -0.34 to -0.37%/°C. TOPCon: -0.30 to -0.33%/°C. HJT: -0.24 to -0.28%/°C. Lower coefficient = better hot weather performance.
Why does temperature reduce output?
Higher temperature increases band gap absorption and reduces voltage. Less power per kWp at hot operating conditions.
How hot do solar panels get?
Indian summer noon: 60-80°C cell temperature, 30-40°C above ambient. Winter: 40-50°C peak.
What is Voc coefficient?
Open-circuit voltage temperature coefficient. PERC: -0.27 to -0.30%/°C. TOPCon: -0.25 to -0.28%/°C. HJT: -0.21 to -0.25%/°C.
Is Isc coefficient positive or negative?
Slightly positive: +0.04 to +0.06%/°C. Current increases slightly with temperature, while voltage drops more, so power drops.
How is power loss calculated?
ΔP = Pmax × β × (T_cell - 25), where β is Pmax coefficient and T_cell is operating cell temperature.
Does HJT beat PERC in heat?
Yes. At 60°C cell temp: HJT loses 9-10%, PERC loses 12-13%. Significant difference in hot Indian summer.
Is bifacial coefficient same as monofacial?
Yes, similar. Bifacial gain comes from rear-side capture, not different temperature behaviour.
Does temperature coefficient improve with new cells?
Yes. PERC → TOPCon → HJT shows progressive improvement.
How is coefficient measured?
Per IEC 61853, measured at multiple temperatures and irradiance. STC plus elevated temperature points.
Does coefficient depend on irradiance?
Approximately constant. Slight dependence usually ignored for engineering calculations.
Are bifacial back side coefficients same?
Yes, similar to front-side coefficient.
Does coefficient affect string sizing?
Yes. Voc coefficient drives cold-temperature string Voc check. Pmax coefficient affects hot-temperature yield.
Is lower coefficient worth premium?
In hot Indian climates: yes. HJT's better coefficient provides 2-4 percent more annual yield in dry hot regions.
Nirav Dhanani
Written by
Nirav Dhanani · CEO

Co-founder & CEO driving Qbits Energy's product strategy and growth across India.

Continue researching this solar decision

Use the related definitions and guides to check the assumptions, sources and requirements for your project.