A solar inverter temperature-derating curve shows how available output changes with a specified temperature condition for an exact model. Read the axes, test conditions, full-output region, reduction region and recovery notes before estimating any loss. An operating-temperature range or IP rating cannot substitute for that curve.
The current public Qbits datasheets identify model families and several electrical fields, but they do not provide a complete temperature-output curve for every model. This guide therefore teaches the review method without inventing a Qbits threshold or summer-loss percentage.
What does temperature derating mean?
Temperature derating is the controlled reduction of available output under the model’s documented thermal conditions. It can protect components or keep operation within a defined envelope. The controlling temperature may be ambient, inlet, heatsink, internal or semiconductor-related, so the curve label and manual definition matter.
Do not assume every inverter starts reducing output at the same temperature or follows a linear percentage per degree. A curve can depend on DC voltage, AC voltage, power factor, altitude, airflow or other stated conditions. The exact document controls the interpretation.
Temperature derating also differs from module temperature loss. PV modules and inverters have separate temperature behaviour and should remain separate in an energy model.
How do you read an inverter derating curve?
Identify both axes and every stated condition before reading a point from the curve. The horizontal axis may show ambient or internal temperature; the vertical axis may show power, current or a percentage of rated output. Notes may limit the curve to a particular voltage, grid condition or cooling arrangement.
Use this sequence:
- Confirm the exact inverter model and document revision.
- Identify the temperature definition and measurement location.
- Identify the output quantity and base rating on the vertical axis.
- Note the region where the documented output remains unchanged.
- Note where reduction begins and whether the relationship is linear or stepped.
- Read any minimum output, shutdown or recovery condition separately.
- Record qualifying DC voltage, AC voltage, power factor, altitude and cooling notes.
- Confirm whether the curve describes continuous operation or a test condition.
A screenshot of the line without its legend and footnotes is not sufficient design evidence.
Is an operating-temperature range the same as a full-output range?
No. An operating-temperature range states where the manufacturer permits or describes operation under its conditions, while full rated output may apply to a narrower region. The unit may reduce power, change another limit or shut down within portions of the broader operating range.
Ask for both the operating range and the output-versus-temperature information. Also check whether the datasheet lists storage temperature, which does not describe powered operation.
The inverter datasheet guide explains the same distinction for maximum values and operating windows on the DC side.
How is normal derating distinguished from a thermal fault?
Use the event log, manual state description, temperature channel and time-aligned power data. Normal derating should follow the model’s documented behaviour under applicable conditions. A thermal warning, abnormal fan state, unexpected shutdown, damaged enclosure or repeated event outside that envelope needs qualified diagnosis.
Collect these records without opening the equipment:
| Evidence | Question it helps answer |
|---|---|
| Exact model and firmware | Which manual and curve apply? |
| Event code and timestamp | Was a thermal state explicitly reported? |
| Ambient and available internal temperature channels | Which temperature changed? |
| DC voltage, current and power | Was array input available? |
| AC power and control limit | Was output limited by another command? |
| Grid voltage and frequency events | Did grid conditions cause reduction or trip? |
| Irradiance or comparable reference | Was solar input itself falling? |
| Site photos and clearances | Does mounting match the manual? |
The overheating guide covers safe owner observations and escalation.
What else can look like temperature derating?
Clipping, export control, curtailment, grid-response functions, shading, soiling, string mismatch and data gaps can resemble a heat-related output reduction. Diagnose these possibilities from synchronized measurements and state information. A summer date or midday timing alone does not establish thermal causation.
For example, a flat AC-power trace may reflect the rated AC limit rather than a temperature curve. A falling trace can reflect moving cloud or grid-voltage response. An offline monitoring interval can draw a misleading straight line. Keep the analysis tied to the inverter’s reported state and available input.
How should the installation environment be reviewed?
Compare the actual mounting location with every environmental and clearance condition in the exact manual. Review solar exposure, shade, airflow, wall or enclosure arrangement, nearby heat sources, dust, altitude, orientation, access and whether multiple units affect one another. Do not invent a universal clearance or canopy design.
The review should record:
An IP65 versus IP66 comparison can explain ingress codes, but it cannot decide thermal placement.
What does a documented site-selection example look like?
A site-selection example compares candidate locations against the same model manual, not against a generic temperature promise. Suppose Location A has direct afternoon sun and restricted airflow, while Location B is shaded, accessible and meets the documented clearances. The record should identify which manual conditions each location satisfies.
Use a table rather than an invented loss percentage:
| Site factor | Location A | Location B | Model requirement or evidence |
|---|---|---|---|
| Direct solar exposure | Observed | Observed | Manual placement instruction |
| Clearance and airflow | Measured | Measured | Exact model manual |
| Nearby heat sources | Surveyed | Surveyed | Site risk review |
| Ambient measurement basis | Defined | Defined | Project design basis |
| Cable and service access | Checked | Checked | Installation and maintenance plan |
| Environmental limits | Pass/pending | Pass/pending | Datasheet and manual |
If both locations pass, an energy model may compare them only when a manufacturer curve and credible local temperature inputs are available. Without those inputs, document the qualitative preference and evidence gap rather than inventing kilowatt-hours.
How should derating be represented in an energy model?
Use the manufacturer curve under its stated conditions and a documented time-series temperature input. Keep module temperature effects, inverter conversion efficiency, clipping and thermal output limiting as separate model components. Validate that the software interprets the curve and temperature definition correctly.
Retain:
- Curve source, model and revision.
- Temperature dataset, resolution and measurement definition.
- Installation-temperature adjustment, if used, with evidence.
- Interactions with DC availability and AC limits.
- Model version and output files.
- Sensitivity cases for uncertain thermal inputs.
Do not replace a missing curve with a generic rate presented as a Qbits fact. Ask the manufacturer for current technical support material or leave the numerical outcome unresolved.
What should EPCs request during procurement?
Request the exact model’s thermal curve, conditions, installation manual and support interpretation when heat performance can affect the design. Add the curve and approved mounting conditions to the technical submittal, then carry them into commissioning and handover. Record missing evidence before selection.
The procurement file should confirm:
- Exact model and revision.
- Operating and storage temperature fields.
- Full-output and derating curve with axis definitions.
- Altitude or voltage qualifications.
- Cooling method and maintenance requirements.
- Mounting orientation and clearances.
- Temperature-related event codes and support route.
- Warranty exclusions relevant to installation environment.
Download current Qbits datasheets and request the exact manual or curve where the public file is incomplete. Engineering and product owners should approve any modelled thermal result.
Sources checked 23 September 2026: the current Qbits public datasheet library, Qbits datasheet-reading guide, overheating guide and ingress-protection guide. This page does not state universal derating temperatures, loss rates or energy savings, because those depend on model level curves that must be read from the datasheet for the exact model.
Qbits inverters for this guide
Specs below come from each model's datasheet. Confirm the exact model and current written terms with Qbits before you buy.
QB 1.5/2.0/2.7/3.0/3.3/3.6/4.0KTLS
- Power
- 1.5–4 kW
- Phase
- Single-phase
- MPPT
- Single-MPPT
QB 4.2/4.6/5/5.4/6KTLS
- Power
- 4.2–6 kW
- Phase
- Single-phase
- MPPT
- Single-MPPT
QB 5/6/8/10/12/15/17KTLC
- Power
- 5–17 kW
- Phase
- Three-phase
- MPPT
- Dual-MPPT
Frequently Asked Questions
What is temperature derating in a solar inverter?
Is thermal derating the same as an overheating fault?
How can I tell whether an inverter is derating?
Does an IP66 rating prevent temperature derating?
Where can I find the derating curve?