GHI

Quick Definition

Global Horizontal Irradiance (GHI) is the total solar radiation received on a horizontal surface, equal to the sum of direct, diffuse and ground-reflected components. Measured in W/m² at any instant or kWh/m² over time. Indian GHI annual totals range from 1,200 to 2,200 kWh/m² depending on region.

Quick Facts

Term
GHI
Category
Solar Resource
Industry
Solar Resource Assessment
Primary Use
Solar resource quantification
Common Users
Designers, EPCs, IPPs, modellers
Standards
ISO 9060, IEC 61724
Related Technologies
Pyranometer, satellite-derived irradiance, NIWE Atlas

What is GHI

Global Horizontal Irradiance (GHI) is the total solar radiation received on a horizontal surface at the Earth’s surface. It is the sum of direct beam radiation (Direct Normal Irradiance projected onto horizontal), diffuse radiation from the sky (Diffuse Horizontal Irradiance) and ground-reflected radiation (typically negligible for horizontal-facing).

GHI is measured in W/m² as instantaneous irradiance, or in kWh/m² as integrated irradiation over time. Daily GHI in India averages 4.5 to 6.5 kWh/m²; annual GHI ranges from 1,200 to 2,200 kWh/m² depending on region.

For Indian solar resource assessment, GHI is the foundational measurement, tracked in detail in QBits’ state-wise solar irradiance data. Plane-of-array irradiance (the irradiance actually hitting the tilted module) is derived from GHI, DNI and DHI through geometric transformations.

Why GHI matters

Solar resource baseline. GHI defines how much solar energy is available at a site, a figure worth cross-checking with QBits’ guide to maximising solar output in Indian climate conditions.

Yield modelling. P50 and P90 yield models use GHI as primary input.

Plant siting. High-GHI regions favour utility-scale solar plants.

Performance benchmarking. Performance Ratio is normalised against plane-of-array irradiance derived from GHI.

PPA tariff modelling. Higher-GHI sites can support lower PPA tariffs.

CUF prediction. CUF correlates strongly with GHI, as shown across the state benchmarks in QBits’ solar yield in India report.

GHI equation

Where:

  • DNI = Direct Normal Irradiance
  • θz = solar zenith angle
  • DHI = Diffuse Horizontal Irradiance

Technical deep dive

Indian GHI by region (annual, kWh/m²)

Annual GHI by Indian region, kWh/m²
RegionAnnual GHI
Western Rajasthan, Kutch2,000 to 2,200
Ladakh, Spiti2,000 to 2,400 (altitude effect)
Andhra Pradesh, Telangana1,800 to 1,950
Karnataka, Tamil Nadu1,750 to 1,900
Maharashtra, MP, Chhattisgarh1,700 to 1,850
Gujarat (non-Kutch)1,800 to 1,950
Delhi, Haryana, Punjab1,650 to 1,800
Uttar Pradesh, Bihar1,500 to 1,750
West Bengal, Odisha1,500 to 1,700
Kerala, Goa1,500 to 1,750
North-east states1,200 to 1,500

GHI vs PSH

Peak Sun Hours (PSH) = GHI / 1 kW/m²

Seasonal variation

Approximate monthly GHI for Delhi, kWh/m²/day
MonthApproximate Delhi GHI (kWh/m²/day)
January4.0
February4.8
March5.8
April6.5
May6.8
June5.5 (monsoon onset)
July4.5 (monsoon peak)
August4.0 (monsoon)
September4.8
October5.2
November4.3
December3.8

GHI measurement

Ways to measure or estimate GHI
InstrumentDescription
Thermopile pyranometer (Class A)High-accuracy reference
Silicon-cell pyranometer (Class B/C)Lower cost, spectrum-limited
Satellite-derivedSpatial coverage
Reanalysis data (ERA5)Historical archive

Data sources

GHI data sources and their coverage
SourceCoverage
NIWE Solar Resource AtlasIndia ground stations
SolargisGlobal satellite-derived
NSRDBGlobal, including India
MeteonormGlobal synthesis
ISRO Bhuvan SolarIndian satellite-derived

Real-world applications

Solar plant siting and pre-feasibility.

Bankable yield modelling for project finance.

PR calculation for plant performance.

State-wise solar policy benchmarking.

Tariff order LCOE inputs.

Residential rooftop sizing, often estimated with a solar cost and savings calculator before a formal proposal is issued.

GHI quality classifications

Pyranometer quality classes and their use
ClassStandardUse
Class A (Secondary Standard)ISO 9060Reference, scientific
Class B (First Class)ISO 9060Commercial plants
Class C (Second Class)ISO 9060Indicative
Reference cellIEC 60904Calibration

Common GHI problems

Soiled pyranometer reading low.

Shading on pyranometer (intermittent).

Calibration drift over years.

Satellite-derived GHI errors in cloudy regions.

Conversion errors between GHI and POA.

Best practices

Install calibrated pyranometers in array plane.

Clean sensors regularly.

Use ground-validated satellite data for long-term averages.

Apply P50 and P90 GHI for yield modelling.

Document GHI source and version in yield reports.

Match temporal resolution to project needs (hourly minimum for plant modelling).

Indian market context

NIWE operates a network of ground-based solar resource stations across India.

Solargis and NSRDB provide commercial satellite-derived GHI data for bankable yield modelling.

ISRO Bhuvan Solar provides free Indian satellite GHI data.

Major Indian utility solar projects use Solargis or Meteonorm P50/P90 data.

SECI tender bid documents reference GHI data for capacity allocation by state, and are typically supported by formal engineering resource center documentation during due diligence.

Standards and certifications

Standards and methods behind GHI measurement
StandardScope
ISO 9060Pyranometer classification
IEC 61724-1Performance monitoring including irradiance
WMO CIMO GuideMeteorological measurement
NREL NSRDB methodologySatellite-derived GHI

Common mistakes

Using one year of GHI data instead of multi-year averages.

Confusing GHI with POA irradiance.

Skipping P90 sensitivity for project finance.

Treating satellite-derived data as fully ground-validated.

Ignoring soiling and shading on pyranometer.

Key takeaways

GHI is the foundational solar resource measurement, the total solar radiation hitting a horizontal surface. Indian GHI ranges from 1,200 kWh/m²/year in the north-east to over 2,200 in western Rajasthan and Ladakh. GHI is the primary input to yield modelling, plant siting and PPA tariff calculation. Calibrated measurements, multi-year averages and proper sensor maintenance determine bankable resource assessment.

Further reading

For how GHI plays out in real projects, these guides go deeper:

Sources

  • NIWE Solar Resource Atlas.
  • ISO 9060, Pyranometer classification.
  • IEC 61724-1, Performance monitoring.
  • Solargis Solar Resource Database.
  • NSRDB National Solar Radiation Database, NREL.
  • Meteonorm Global Solar Radiation Database.
  • ISRO Bhuvan Solar.
  • WMO Guide to Meteorological Instruments.
  • IEA PVPS Task 16 Report on Solar Resource for High-Penetration Applications.
FAQ

Frequently Asked Questions

What is GHI in simple words?
How much solar energy hits a flat horizontal surface each day or year. The standard baseline measure of how sunny a location is.
What is the unit of GHI?
Irradiance in W/m² at an instant. Irradiation in kWh/m² over time (typically daily or annual).
What is the difference between GHI, DNI and DHI?
GHI = DNI × cos(zenith) + DHI. GHI is total on horizontal. DNI is direct beam. DHI is diffuse sky radiation.
What is the average Indian GHI?
1,700 to 1,900 kWh/m² per year for most of India. Higher in western Rajasthan and Ladakh (above 2,000), lower in north-east and coastal (1,400 to 1,600).
Which Indian regions have highest GHI?
Western Rajasthan (Jaisalmer, Bikaner), Ladakh, Gujarat (Kutch), parts of Telangana and Andhra Pradesh.
How is GHI measured?
Pyranometer mounted horizontally. Modern stations record at 1-minute intervals.
What is satellite-derived GHI?
Estimated from cloud cover, atmospheric models and surface measurements. Used where ground stations are sparse.
Is GHI same as irradiation?
Irradiation is the time integral of irradiance. GHI specifically refers to the horizontal-plane component.
What is plane-of-array irradiance?
Irradiance on the tilted PV module surface. Computed from GHI, DNI and DHI through geometric models.
Why does Indian GHI vary by region?
Latitude, monsoon rainfall, dust load, altitude and cloud patterns. Western India is sunnier than eastern; Ladakh has very high GHI due to altitude.
How does GHI vary seasonally?
Peaks in April to May. Drops during monsoon (June to September). Stable but lower in winter.
What is the typical Indian daily GHI?
4.5 to 6.5 kWh/m²/day average annual. Up to 8 kWh/m²/day in summer in dry regions.
How does GHI affect solar yield?
Yield is roughly proportional to GHI. Doubling GHI roughly doubles annual generation for the same plant.
Where can I find Indian GHI data?
NIWE Solar Resource Atlas, NSRDB, Solargis, Meteonorm.
What is the relationship between GHI and PSH?
PSH (peak sun hours) is GHI / 1000 W/m². Roughly equal to GHI in kWh/m²/day.
Nirav Dhanani
Written by
Nirav Dhanani · CEO