The best solar inverter for an AC or heavy-load home depends first on what “run” means. If the grid is present and the goal is to reduce the electricity bought for daytime cooling, a correctly designed on-grid system may be enough. If the AC must stay on during a power cut, the decision shifts to a hybrid inverter’s backup output, short-duration capability, battery, protected circuits, and the AC’s exact starting behaviour.

For a current 5 kW single-phase hybrid shortlist, GoodWe GW5000-ES-20, Qbits QBH-5KS48P, and Growatt SPH 5000TL BL-UP publish materially different evidence. GoodWe publishes 5,000 VA nominal backup output. Qbits publishes 5,000 W in its rated off-grid apparent-output row and greater than 200% for 15 seconds in the maximum-output row. Growatt publishes a clear 4,000 W maximum backup ceiling despite the 5 kW model name.

Qbits publishes this article and sells the QBH-5KS48P. That commercial interest is disclosed before the shortlist. We did not test these inverters with an air conditioner, inspect installations, verify battery compatibility, or compare local prices, warranties, stock, service outcomes, certificate validity, or DISCOM acceptance.

First decide: bill offset or outage backup

These are different electrical jobs.

Three AC goals and what supplies the AC in each
Homeowner goalWhat supplies the ACMain design question
Reduce daytime AC purchases while the grid is availableSolar, with the grid balancing shortfalls and startsDoes the array’s expected energy align with daytime demand and the approved grid connection?
Offset night use through billing creditsGrid at night, subject to the applicable metering arrangementWhat do the current tariff and metering rules credit?
Keep the AC running during a power cutIsolated hybrid backup output plus battery and available solarCan the exact inverter and battery support continuous load, the start event, and required duration?

An ordinary on-grid inverter does not become a backup source because the sun is shining. It stops energising the utility-connected circuit after grid loss. If outage cooling is the requirement, compare exact hybrid backup specifications and a protected-load design.

That distinction prevents the most expensive category mistake: buying an efficient grid-tied inverter for an outage problem it was never intended to solve.

Our method for an AC and heavy-load shortlist

A broad brand ranking would hide the fields that decide whether an AC starts. We used five gates:

  1. Same class. Each shortlisted model is a named 5 kW-class, single-phase, low-voltage hybrid inverter.
  2. Current primary evidence. The exact model must appear on a current manufacturer page or datasheet.
  3. A separate backup figure. Grid output cannot stand in for the rating at the backup terminals.
  4. Battery and PV evidence. The source must publish battery voltage or current plus MPPT information.
  5. Unknowns stay unknown. We do not infer approved batteries, local stock, warranty remedies, AC compatibility, or service quality from a brand name.

The reading order is GoodWe, Qbits, Growatt. It is not alphabetical, and Qbits is deliberately not first. It is not a paid position, reliability score, sales ranking, or universal winner.

Exact 5 kW hybrid comparison for AC backup

The values below come from the current GoodWe ES G2 product page, Qbits QBH single-phase catalogue, and Growatt SPH TL BL-UP datasheet, checked on 26 September 2026.

Published backup, short-duration, battery and PV figures for three exact 5 kW-class hybrid models, in each manufacturer’s own units
Exact modelPublished backup outputPublished short-duration or heavy-load figureBattery inputPV trackingWhat to confirm
GoodWe GW5000-ES-205,000 VA nominal backup apparent powerProduct page says the family supports heavy loads such as air conditioners; the exact peak value is not shown in the product page table40 to 60 V; 120 A maximum continuous charge or discharge2 MPPTs; 16 A maximum input per MPPTAC start must be checked against a current detailed datasheet or manual, exact battery list, and site load schedule
Qbits QBH-5KS48P5,000 W in the catalogue’s rated off-grid apparent-output rowGreater than 200% for 15 seconds in the family’s maximum-output-apparent-power row48 V rated; configurable charge voltage up to 60 V; 120 A maximum charge or discharge2 MPPTs; 18 A maximum input per trackerUnits are quoted as the catalogue prints them; confirm the exact battery pairing, current manual and written warranty
Growatt SPH 5000TL BL-UP4,000 W maximum backup AC outputNo separate peak figure in the datasheet42 to 59 V; 85 A maximum charge and discharge; 4,000 W continuous charging and discharging power2 MPPTs; 13.5 A maximum input per trackerIndia availability, exact battery pairing, starting duty, and local terms need confirmation
A050100150GoodWe GW5000-ES-20120 AQbits QBH-5KS48P120 AGrowatt SPH 5000TL BL-UP85 AA050100150GoodWeGW5000-ES-20120 AQbits QBH-5KS48P120 AGrowatt SPH5000TL BL-UP85 A
Maximum battery charge or discharge current published for each model
ItemValue (A)
GoodWe GW5000-ES-20120 A
Qbits QBH-5KS48P120 A
Growatt SPH 5000TL BL-UP85 A
Maximum battery charge or discharge current published for each modelSource: GoodWe ES G2 product page, Qbits QBH single-phase catalogue and Growatt SPH 3000-6000TL BL-UP datasheet (April 2026), as cited in this article, checked 26 September 2026GoodWe figure is continuous. Current alone does not set usable power; battery voltage, BMS limits and approved pairing also apply.

Do not silently treat W and VA as the same unit. Real power, apparent power, power factor, waveform, and duration all matter with motor loads. The table preserves the units each manufacturer publishes.

Conditional verdicts, not a universal winner

GoodWe GW5000-ES-20: strongest public 5 kVA continuous comparison point

GoodWe’s exact model table publishes 5,000 VA maximum grid apparent output and 5,000 VA nominal backup apparent power. It also gives a 40 to 60 V battery range, 120 A maximum continuous charge or discharge current, and 16 A maximum PV input per MPPT.

The product page says ES G2 can switch to backup in less than 10 ms and is intended to withstand heavy loads such as air conditioners. That supports putting the model on the shortlist. It does not provide the exact peak apparent power, duration, or AC compressor compatibility in the reviewed model table.

Conditional verdict: shortlist GW5000-ES-20 when the designed continuous backup load fits 5,000 VA and the supplier provides the current detailed short-duration-output evidence, approved battery record, and exact load check before purchase.

Qbits QBH-5KS48P: a published short-duration row

The Qbits catalogue identifies QBH-5KS48P as a single-phase model with 5,000 W in its rated off-grid apparent-output row. It prints greater than 200% for 15 seconds in the family’s maximum-output-apparent-power row. The same exact model column publishes a 48 V rated battery input, up to 60 V configurable charging voltage, 120 A maximum battery charge or discharge current, two MPPTs, and 18 A input per tracker.

This is the only short-duration figure printed in the three sources. It is still not permission to connect any AC. The catalogue uses W in a row labelled apparent power, does not publish an exact approved battery list, and does not state whether the battery can supply the corresponding current. The designer must close those gaps.

The brochure also prints a switching statement as “within 10 seconds.” That wording is not used here as a transfer-time promise because it needs manufacturer clarification. A decimal or unit should never be silently repaired in a safety-relevant purchase decision.

Conditional verdict: shortlist QBH-5KS48P when a qualified review confirms the exact model’s short-duration output, compatible battery power, AC start event, and protected-load design. Review the current Qbits hybrid inverter family only after those inputs are available.

Growatt SPH 5000TL BL-UP: useful when 4 kW backup is enough

Growatt makes a common naming trap visible. SPH 5000TL BL-UP publishes 5,000 W maximum grid-side AC output but only 4,000 W maximum backup AC output. It also publishes 42 to 59 V battery input, 85 A maximum charge and discharge current, 4,000 W continuous charging and discharging power, two MPPTs, and 13.5 A per tracker.

The lower backup number is not automatically a defect. A home with a deliberately limited protected-load board may fit it. It is simply a hard design constraint that the 5 kW product name does not reveal.

Conditional verdict: shortlist SPH 5000TL BL-UP only when 4,000 W of published backup power covers the continuous load and the supplier supplies exact starting-duty and battery-pairing evidence. Do not use its 5,000 W grid rating to approve 5,000 W of outage load.

Tonnage is not an inverter-sizing input

A 1.5 ton or 2 ton label describes cooling capacity. Two ACs with the same tonnage can publish different rated input, maximum input, current, control method, and starting behaviour. Room temperature, thermostat setting, compressor speed, maintenance, and ambient conditions can also change actual energy use.

Record these fields for the exact AC:

Fields to record for the exact air conditioner and how each is used in the design
InputPreferred evidenceDesign use
Exact AC modelNameplate and current manufacturer sheetPrevents using a generic tonnage estimate
Rated and maximum inputExact product dataSets continuous-load cases
Rated current and power factorExact product dataSupports current and apparent-power checks
Starting current or short-duration demandManufacturer technical data or competent measurementTests the inverter and battery start event
Operating scheduleOwner requirement or monitoringDrives daily energy and backup duration
Simultaneous appliancesProtected-load schedulePrevents sizing for the AC alone

A transparent heavy-load sizing example

The following is an illustration of the method, not a typical Indian home and not a recommendation for a particular inverter.

Change any input and the result changes. A second AC, pump, induction cooktop, water heater, or electric-vehicle charger can move both the continuous and starting case. The solar inverter sizing guide covers the broader load and array sequence.

The battery must pass power and energy checks

Battery sizing for AC backup has two separate tests:

  1. Power: Can the battery and its management system deliver the current required by the inverter during continuous operation and the compressor start?
  2. Energy: After the allowed depth of discharge, reserve, conversion losses, temperature, and ageing allowance, is enough usable energy left for the required hours?

A large kilowatt-hour label can still fail the power test. A battery that can deliver high power can still be too small for the duration target. The exact inverter and battery pairing must also be approved in current manufacturer documentation, including communication protocol and firmware where applicable.

Use the battery sizing worksheet to make each assumption visible. Treat the result as a design input, not a promised runtime.

How to size solar for daytime AC use

Panel quantity comes from energy, roof conditions, and the inverter’s PV limits, not the AC’s tonnage. Estimate the AC’s daily kilowatt-hours from exact product data or monitoring, add the rest of the site’s demand, and model the proposed array for location, orientation, shade, temperature, and losses.

Then check the exact module string against:

  • maximum DC voltage after cold-temperature correction;
  • MPPT operating range during expected hot and cold conditions;
  • maximum input current and short-circuit-current limit;
  • maximum or recommended PV power for the exact inverter;
  • clipping objective and grid-export constraint.

For grid-connected bill offset, the grid can cover a temporary shortfall or compressor start while it is available. For isolated backup, the inverter and battery must carry the event themselves. Do not copy an on-grid array calculation into an outage-backup approval.

Heavy loads need a protected-load plan

“Whole-home backup” is not an equipment specification. List the circuits that remain live and identify which combinations are permitted. An AC-heavy home may also have pumps, refrigeration, microwaves, kettles, induction cooking, geysers, or vehicle charging. Several can start or switch on together.

A useful backup schedule records:

  • exact appliance or circuit;
  • maximum running input;
  • power factor or apparent power where relevant;
  • starting demand and duration;
  • allowed simultaneous combinations;
  • priority and automatic or manual load shedding;
  • phase allocation;
  • whether the circuit is backed up or grid-only.

Staggering loads can reduce the required short-duration capacity, but only if the control is actually specified and commissioned. A verbal instruction to “avoid using everything together” is not a control strategy.

What the quote must prove

Before selecting any model, ask the supplier for:

Reject the quote if it uses only “5 kW hybrid,” sizes from AC tonnage, equates grid output with backup output, or promises runtime without showing the battery assumptions.

Final recommendation

For daytime AC bill reduction with a reliable grid, start with an on-grid energy and string design. Do not pay for backup solely because the home contains an AC.

For AC operation during outages, begin with the exact load and start event. GoodWe GW5000-ES-20 is the clearest 5 kVA continuous backup comparison point, but its detailed peak evidence must be obtained. Qbits QBH-5KS48P is the only one of the three that prints a short-duration row, but the source wording, battery pairing, and exact start duty need technical confirmation. Growatt SPH 5000TL BL-UP is a defensible option when its explicit 4,000 W backup ceiling covers the designed load.

Choose none of them yet if the supplier cannot demonstrate the exact AC start, battery power, backup output, and protected-load plan. The right inverter is the one that passes those checks, not the one with the largest number in its model name.

Qbits models

Specs below come from each model's datasheet. Confirm the exact model and current written terms with Qbits before you buy.

Browse all on-grid inverters →

FAQ

Frequently Asked Questions

Which solar inverter is best for running an AC?
There is no brand-wide winner. For outage backup, compare the exact model's continuous backup output, documented short-duration output, battery discharge limit, phase, and approved battery pairing against the AC and every simultaneous load. For daytime bill offset with the grid present, an on-grid design may be sufficient and should be sized from energy use and the PV array rather than from backup surge.
Can an on-grid solar inverter run an AC during a power cut?
An ordinary on-grid inverter stops energising the utility-connected circuit after grid loss. Daytime sunlight does not create backup by itself. Running an AC during an outage needs an approved hybrid or backup output, isolation, sufficient continuous and short-duration power, and a compatible battery or other supported energy source.
What size inverter is needed for a 1.5 ton AC?
Tonnage describes cooling capacity, not electrical input. Use the exact AC model's maximum input and starting-current or short-duration demand, then add every load that may run at the same time. Compare those values with the exact inverter's backup-output rows. A universal inverter size based only on 1.5 ton is not defensible.
How large should the battery be for AC backup?
Start with the AC's measured or manufacturer-stated electrical input, expected duty cycle, other backup loads, and required hours. Then account for usable battery energy, discharge-power limits, inverter losses, reserve, temperature, and ageing. The inverter and battery must pass both the energy and instantaneous-power checks.
Is a 5 kW hybrid inverter always able to supply 5 kW during an outage?
No. Grid-side and backup-side ratings can differ. In the exact models compared here, Growatt publishes 5,000 W maximum grid output but 4,000 W maximum backup output for SPH 5000TL BL-UP. Read the backup row rather than relying on the model name.
Does Qbits publish a surge rating for QBH-5KS48P?
The current Qbits catalogue prints greater than 200% for 15 seconds in the off-grid maximum-output-apparent-power row for the family. Treat that as a manufacturer declaration that requires technical review, compatible battery evidence, and confirmation for the exact supplied unit. It is not proof that every AC will start or that a 5 kW home can be backed up without a load study.