The best solar inverter for an AC or heavy-load home depends first on what “run” means. If the grid is present and the goal is to reduce the electricity bought for daytime cooling, a correctly designed on-grid system may be enough. If the AC must stay on during a power cut, the decision shifts to a hybrid inverter’s backup output, short-duration capability, battery, protected circuits, and the AC’s exact starting behaviour.
For a current 5 kW single-phase hybrid shortlist, GoodWe GW5000-ES-20, Qbits QBH-5KS48P, and Growatt SPH 5000TL BL-UP publish materially different evidence. GoodWe publishes 5,000 VA nominal backup output. Qbits publishes 5,000 W in its rated off-grid apparent-output row and greater than 200% for 15 seconds in the maximum-output row. Growatt publishes a clear 4,000 W maximum backup ceiling despite the 5 kW model name.
Qbits publishes this article and sells the QBH-5KS48P. That commercial interest is disclosed before the shortlist. We did not test these inverters with an air conditioner, inspect installations, verify battery compatibility, or compare local prices, warranties, stock, service outcomes, certificate validity, or DISCOM acceptance.
First decide: bill offset or outage backup
These are different electrical jobs.
| Homeowner goal | What supplies the AC | Main design question |
|---|---|---|
| Reduce daytime AC purchases while the grid is available | Solar, with the grid balancing shortfalls and starts | Does the array’s expected energy align with daytime demand and the approved grid connection? |
| Offset night use through billing credits | Grid at night, subject to the applicable metering arrangement | What do the current tariff and metering rules credit? |
| Keep the AC running during a power cut | Isolated hybrid backup output plus battery and available solar | Can the exact inverter and battery support continuous load, the start event, and required duration? |
An ordinary on-grid inverter does not become a backup source because the sun is shining. It stops energising the utility-connected circuit after grid loss. If outage cooling is the requirement, compare exact hybrid backup specifications and a protected-load design.
That distinction prevents the most expensive category mistake: buying an efficient grid-tied inverter for an outage problem it was never intended to solve.
Our method for an AC and heavy-load shortlist
A broad brand ranking would hide the fields that decide whether an AC starts. We used five gates:
- Same class. Each shortlisted model is a named 5 kW-class, single-phase, low-voltage hybrid inverter.
- Current primary evidence. The exact model must appear on a current manufacturer page or datasheet.
- A separate backup figure. Grid output cannot stand in for the rating at the backup terminals.
- Battery and PV evidence. The source must publish battery voltage or current plus MPPT information.
- Unknowns stay unknown. We do not infer approved batteries, local stock, warranty remedies, AC compatibility, or service quality from a brand name.
The reading order is GoodWe, Qbits, Growatt. It is not alphabetical, and Qbits is deliberately not first. It is not a paid position, reliability score, sales ranking, or universal winner.
Exact 5 kW hybrid comparison for AC backup
The values below come from the current GoodWe ES G2 product page, Qbits QBH single-phase catalogue, and Growatt SPH TL BL-UP datasheet, checked on 26 September 2026.
| Exact model | Published backup output | Published short-duration or heavy-load figure | Battery input | PV tracking | What to confirm |
|---|---|---|---|---|---|
| GoodWe GW5000-ES-20 | 5,000 VA nominal backup apparent power | Product page says the family supports heavy loads such as air conditioners; the exact peak value is not shown in the product page table | 40 to 60 V; 120 A maximum continuous charge or discharge | 2 MPPTs; 16 A maximum input per MPPT | AC start must be checked against a current detailed datasheet or manual, exact battery list, and site load schedule |
| Qbits QBH-5KS48P | 5,000 W in the catalogue’s rated off-grid apparent-output row | Greater than 200% for 15 seconds in the family’s maximum-output-apparent-power row | 48 V rated; configurable charge voltage up to 60 V; 120 A maximum charge or discharge | 2 MPPTs; 18 A maximum input per tracker | Units are quoted as the catalogue prints them; confirm the exact battery pairing, current manual and written warranty |
| Growatt SPH 5000TL BL-UP | 4,000 W maximum backup AC output | No separate peak figure in the datasheet | 42 to 59 V; 85 A maximum charge and discharge; 4,000 W continuous charging and discharging power | 2 MPPTs; 13.5 A maximum input per tracker | India availability, exact battery pairing, starting duty, and local terms need confirmation |
Do not silently treat W and VA as the same unit. Real power, apparent power, power factor, waveform, and duration all matter with motor loads. The table preserves the units each manufacturer publishes.
Conditional verdicts, not a universal winner
GoodWe GW5000-ES-20: strongest public 5 kVA continuous comparison point
GoodWe’s exact model table publishes 5,000 VA maximum grid apparent output and 5,000 VA nominal backup apparent power. It also gives a 40 to 60 V battery range, 120 A maximum continuous charge or discharge current, and 16 A maximum PV input per MPPT.
The product page says ES G2 can switch to backup in less than 10 ms and is intended to withstand heavy loads such as air conditioners. That supports putting the model on the shortlist. It does not provide the exact peak apparent power, duration, or AC compressor compatibility in the reviewed model table.
Conditional verdict: shortlist GW5000-ES-20 when the designed continuous backup load fits 5,000 VA and the supplier provides the current detailed short-duration-output evidence, approved battery record, and exact load check before purchase.
Qbits QBH-5KS48P: a published short-duration row
The Qbits catalogue identifies QBH-5KS48P as a single-phase model with 5,000 W in its rated off-grid apparent-output row. It prints greater than 200% for 15 seconds in the family’s maximum-output-apparent-power row. The same exact model column publishes a 48 V rated battery input, up to 60 V configurable charging voltage, 120 A maximum battery charge or discharge current, two MPPTs, and 18 A input per tracker.
This is the only short-duration figure printed in the three sources. It is still not permission to connect any AC. The catalogue uses W in a row labelled apparent power, does not publish an exact approved battery list, and does not state whether the battery can supply the corresponding current. The designer must close those gaps.
The brochure also prints a switching statement as “within 10 seconds.” That wording is not used here as a transfer-time promise because it needs manufacturer clarification. A decimal or unit should never be silently repaired in a safety-relevant purchase decision.
Conditional verdict: shortlist QBH-5KS48P when a qualified review confirms the exact model’s short-duration output, compatible battery power, AC start event, and protected-load design. Review the current Qbits hybrid inverter family only after those inputs are available.
Growatt SPH 5000TL BL-UP: useful when 4 kW backup is enough
Growatt makes a common naming trap visible. SPH 5000TL BL-UP publishes 5,000 W maximum grid-side AC output but only 4,000 W maximum backup AC output. It also publishes 42 to 59 V battery input, 85 A maximum charge and discharge current, 4,000 W continuous charging and discharging power, two MPPTs, and 13.5 A per tracker.
The lower backup number is not automatically a defect. A home with a deliberately limited protected-load board may fit it. It is simply a hard design constraint that the 5 kW product name does not reveal.
Conditional verdict: shortlist SPH 5000TL BL-UP only when 4,000 W of published backup power covers the continuous load and the supplier supplies exact starting-duty and battery-pairing evidence. Do not use its 5,000 W grid rating to approve 5,000 W of outage load.
Tonnage is not an inverter-sizing input
A 1.5 ton or 2 ton label describes cooling capacity. Two ACs with the same tonnage can publish different rated input, maximum input, current, control method, and starting behaviour. Room temperature, thermostat setting, compressor speed, maintenance, and ambient conditions can also change actual energy use.
Record these fields for the exact AC:
| Input | Preferred evidence | Design use |
|---|---|---|
| Exact AC model | Nameplate and current manufacturer sheet | Prevents using a generic tonnage estimate |
| Rated and maximum input | Exact product data | Sets continuous-load cases |
| Rated current and power factor | Exact product data | Supports current and apparent-power checks |
| Starting current or short-duration demand | Manufacturer technical data or competent measurement | Tests the inverter and battery start event |
| Operating schedule | Owner requirement or monitoring | Drives daily energy and backup duration |
| Simultaneous appliances | Protected-load schedule | Prevents sizing for the AC alone |
A transparent heavy-load sizing example
The following is an illustration of the method, not a typical Indian home and not a recommendation for a particular inverter.
Change any input and the result changes. A second AC, pump, induction cooktop, water heater, or electric-vehicle charger can move both the continuous and starting case. The solar inverter sizing guide covers the broader load and array sequence.
The battery must pass power and energy checks
Battery sizing for AC backup has two separate tests:
- Power: Can the battery and its management system deliver the current required by the inverter during continuous operation and the compressor start?
- Energy: After the allowed depth of discharge, reserve, conversion losses, temperature, and ageing allowance, is enough usable energy left for the required hours?
A large kilowatt-hour label can still fail the power test. A battery that can deliver high power can still be too small for the duration target. The exact inverter and battery pairing must also be approved in current manufacturer documentation, including communication protocol and firmware where applicable.
Use the battery sizing worksheet to make each assumption visible. Treat the result as a design input, not a promised runtime.
How to size solar for daytime AC use
Panel quantity comes from energy, roof conditions, and the inverter’s PV limits, not the AC’s tonnage. Estimate the AC’s daily kilowatt-hours from exact product data or monitoring, add the rest of the site’s demand, and model the proposed array for location, orientation, shade, temperature, and losses.
Then check the exact module string against:
- maximum DC voltage after cold-temperature correction;
- MPPT operating range during expected hot and cold conditions;
- maximum input current and short-circuit-current limit;
- maximum or recommended PV power for the exact inverter;
- clipping objective and grid-export constraint.
For grid-connected bill offset, the grid can cover a temporary shortfall or compressor start while it is available. For isolated backup, the inverter and battery must carry the event themselves. Do not copy an on-grid array calculation into an outage-backup approval.
Heavy loads need a protected-load plan
“Whole-home backup” is not an equipment specification. List the circuits that remain live and identify which combinations are permitted. An AC-heavy home may also have pumps, refrigeration, microwaves, kettles, induction cooking, geysers, or vehicle charging. Several can start or switch on together.
A useful backup schedule records:
- exact appliance or circuit;
- maximum running input;
- power factor or apparent power where relevant;
- starting demand and duration;
- allowed simultaneous combinations;
- priority and automatic or manual load shedding;
- phase allocation;
- whether the circuit is backed up or grid-only.
Staggering loads can reduce the required short-duration capacity, but only if the control is actually specified and commissioned. A verbal instruction to “avoid using everything together” is not a control strategy.
What the quote must prove
Before selecting any model, ask the supplier for:
Reject the quote if it uses only “5 kW hybrid,” sizes from AC tonnage, equates grid output with backup output, or promises runtime without showing the battery assumptions.
Final recommendation
For daytime AC bill reduction with a reliable grid, start with an on-grid energy and string design. Do not pay for backup solely because the home contains an AC.
For AC operation during outages, begin with the exact load and start event. GoodWe GW5000-ES-20 is the clearest 5 kVA continuous backup comparison point, but its detailed peak evidence must be obtained. Qbits QBH-5KS48P is the only one of the three that prints a short-duration row, but the source wording, battery pairing, and exact start duty need technical confirmation. Growatt SPH 5000TL BL-UP is a defensible option when its explicit 4,000 W backup ceiling covers the designed load.
Choose none of them yet if the supplier cannot demonstrate the exact AC start, battery power, backup output, and protected-load plan. The right inverter is the one that passes those checks, not the one with the largest number in its model name.
Qbits inverters for this guide
Specs below come from each model's datasheet. Confirm the exact model and current written terms with Qbits before you buy.
QB 1.5/2.0/2.7/3.0/3.3/3.6/4.0KTLS
- Power
- 1.5–4 kW
- Phase
- Single-phase
- MPPT
- Single-MPPT
QB 4.2/4.6/5/5.4/6KTLS
- Power
- 4.2–6 kW
- Phase
- Single-phase
- MPPT
- Single-MPPT
QB 5/6/8/10/12/15/17KTLC
- Power
- 5–17 kW
- Phase
- Three-phase
- MPPT
- Dual-MPPT
Frequently Asked Questions
Which solar inverter is best for running an AC?
Can an on-grid solar inverter run an AC during a power cut?
What size inverter is needed for a 1.5 ton AC?
How large should the battery be for AC backup?
Is a 5 kW hybrid inverter always able to supply 5 kW during an outage?
Does Qbits publish a surge rating for QBH-5KS48P?
Keyur Rakholiya CTO, Qbits Energy
Listed by Qbits as its CTO. Current role, technical responsibilities and credentials require confirmation by the company owner.