Rajkot Cold Storage Solar: 40 kW Planning Scenario

Illustrative 40 kW Rajkot cold storage solar planning scenario. It is not a verified Qbits customer installation or result.

Q
Qbits Editorial
June 5, 2026 Updated October 14, 2026 7 min read

Cold storage has continuous refrigeration duty, cycling compressors and potentially sensitive controls. This scenario tests a 40 kW working brief without presenting an invented facility, bill or operating result.

What decision does this scenario test?

The question is not whether 40 kW “works” in the abstract. The question is whether that AC capacity, paired with a documented PV array and connection design, fits the site’s measured daytime load, available area, electrical infrastructure and approval route.

A credible answer must be electrically safe, acceptable under the current project process, and commercially supportable after every cost and uncertainty is shown.

Evidence required before sizing

Evidence to collect before sizing the 40 kW cold-storage scenario, with status
InputWhat to collectStatus in this scenario
Compressor profileInterval kW, starts, duty cycle and seasonal behaviourTo be collected
Power qualityVoltage, current, power factor and harmonic measurementsTo be collected
Continuity requirementTemperature tolerance, alarms, generator and recovery procedureTo be collected
Tariff and billingTwelve months of bills, tariff category, demand charges and export treatmentTo be collected
Site constraintsSurvey, shading, structure, cable route, access and environmentTo be collected
Utility processCurrent connection, metering and inspection requirementsTo be collected
Commercial scopeItemised quote, taxes, exclusions, warranty and service dutiesTo be collected

A missing input should stay marked as unknown. Replacing it with a typical value creates a neat result but not a reliable decision.

Engineering controls for this site

  • Do not assume a grid-tied inverter drives compressor motors or supplies them during an outage.
  • Review motor starts, VFD interaction and protection at the point of common coupling.
  • Keep cold-chain continuity under a tested facility emergency plan.

The refrigeration contractor and electrical designer should review the same measured data. A headline inverter THD value is not a site power-quality study, and no universal Qbits THD claim is supported.

The responsible electrical professional should sign the single-line diagram, protection settings and commissioning plan. Any safety-critical or production-critical system needs an independent continuity plan. Grid-connected solar is not backup unless the complete design explicitly supports that role.

How should the commercial case be calculated?

Use measured inputs and keep the calculation reproducible:

  1. Estimated annual generation = simulation output for the documented array, orientation, losses and weather dataset.
  2. Self-consumed energy = the lesser of generation and coincident site load in each interval.
  3. Exported energy = generation minus self-consumed energy, subject to the approved metering arrangement.
  4. Annual bill effect = avoided import charges plus documented export credit minus fixed, demand, finance, service and maintenance costs.
  5. Simple payback = eligible project cost divided by annual net cash benefit.

Do not publish a generation, saving, return or payback result until the calculation file identifies every input, unit, date and source. Tax effects require written advice from a qualified professional. Financing results require actual lender terms.

What can be said about Qbits equipment?

Qbits’ published catalogue lists on-grid and hybrid inverter families with model-specific ratings. That does not prove that a Qbits model is suitable for this scenario. Nor does it state universal battery compatibility, transfer time, monitoring functions, harmonic performance, certification, warranty terms, service coverage or project support.

If Qbits is shortlisted, record the exact SKU and request its current datasheet, installation manual, applicable certificates, monitoring scope, written warranty and service terms. Compare those documents with the final design. MNRE’s current ALMM page concerns PV module and cell lists, not an inverter list.

What belongs in the handover record?

Keep approved drawings, the final equipment schedule, utility correspondence, protection settings, test results, commissioning readings, photographs, monitoring ownership, invoices, warranties and service contacts.

The EPC bid checklist helps compare proposals. The commissioning guide covers handover evidence. For a Qbits equipment enquiry, use the datasheet library and contact page.

FAQ

Frequently Asked Questions

Is this 40 kW scenario a real Qbits installation?
No. It is a planning scenario, not a verified customer installation or performance result. Capacity, generation, cost, savings and payback remain unknown until site records and signed project documents are supplied.
Does Qbits recommend 40 kW for this site?
No. The capacity is a working brief only. A qualified designer must use interval load data, sanctioned load, site constraints, the connection arrangement and current utility requirements.
Can this page confirm subsidy, tax or net-metering eligibility?
No. Eligibility and tax treatment depend on the applicant, site, equipment, transaction and rules in force. Verify them through the relevant official authority and qualified adviser.